Manufacturer and exporter of Intubation Instruments
that includes silicone rubber airways, tooth protector, magill forceps, tube
cleaning brushes.
Intubation Instruments
Nasopharyngeal Silicone Rubber Airways
We are Manufacturers & Exporters of
Nasopharyngeal Silicone Rubber Airways , which is used in nasopharyngeal
anatomy .
The Smooth rounded edges ensure no damage to nasal passage, practically no
trauma when inserted into the nose. Kink resistant. Adjustable stop provided
to maintain the exact tube position.
Features
- Size 4mm, Size 5mm, Size 6mm,
- Size 7mm, Size 8mm, Size 9mm
- Conforms readily to nasopharyngeal anatomy. Smooth rounded edges
ensure no damage to nasal passage, practically no trauma when inserted
into the nose. Kink resistant.
- Adjustable stop provided to maintain the exact tube position.
15mm Tracheal Connectors set in a box
We provide 15mm Tracheal Connectors set in a box ,
which includes twenty 15mm Straight Connectors , Double Swivel , M/M Circuit
Adaptor & 15F Catheter Mount & all supplied in a plastic container
to keep each in their assigned slots.
Features
Comprises of twenty 15mm Straight Connectors , 15mmX22mm Double Swivel ,
15/15 M/M Circuit Adaptor & 15F Catheter Mount - all supplied in a
plastic container to keep each in their assigned slots.
Fibrelite Stylet & Handle
Fibrelite Stylet & Handle is Suitable for
orotracheal & nasotracheal intubation.
It is useful in patients whose larynx is difficult or impossible to
visualise by direct laryngoscopy.
Features
- Handle
- Fibrelite Stylet Size 33cms
- Cordless, lightweight, cool & white light, no hot bulb to cause
trauma, useful in patients whose larynx is difficult or impossible to
visualise by direct laryngoscopy. Suitable for orotracheal &
nasotracheal intubation.
Malleable Stylets
Malleable Stylets is made Made from malleable
stainless steel & It is available in three different sizes Small, Medium
& Large to cover the entire range of 2.5mm to 11.00mm tubes.
Features
Set of 3 - S.S.
Available in three different sizes Small, Medium & Large to cover the
entire range of 2.5mm to 11.00mm tubes. Made from malleable stainless steel,
will not form sulphates or oxides or peeling of chromium plating as in
stylets made from copper or aluminium. A plastic handle moulded onto the
stylet provides an easy & firm grip.
Adjustable Stop for Stylet
Adjustable Stop for Stylet is Suitable for all the
three sizes of stylets & It Prevents unintentional advancement of stylet
beyond distal tip of E/T tubes .
Features
Suitable for all the three sizes of stylets. Prevents unintentional
advancement of stylet beyond distal tip of E/T tubes; stylet can be
lengthened or shortened by sliding the stop to desired position.
Bougie
We Manufacture & exports Bougie , Which is
Useful in post extubation or reintroduction of the tube. The Details are
given below.
Features
Size 4mm X 700mm
Aids intubation by directing the tip of the E/T tube into the larygeal
inlet when it is difficult to bring the larynx and vocal cords into view.
Useful in post extubation or reintroduction of the tube. Tube inserted
orally or nasally can be changed using this device.
Tube Cleaning Brushes
Tube Cleaning Brushes is manufactured from
stainless steel wire to avoid rusting and durable nylon bristles to extend
life.
Features
Set of 4 sizes - 4,6,8 & 10mm O/D.
Manufactured of stainless steel wire to avoid rusting and durable nylon
bristles to extend life.
Magill Forceps
Magill Forceps are made from stainless steel.The
handles are specially curved so that operators hand does not obstruct
his view.
Features
Size : Adult 7205 - Size : Child 7206 - Size : Infant
For guiding tracheal tubes under direct vision. The handles are specially
curved so that operators hand does not obstruct his view. The forceps
are made from stainless steel.
Tooth Protector
We are Manufacturers & Exporters of Tooth
Protector , which are useful in protecting the teeth from damage by contact
with flange of the laryngoscope blade and also from getting caught in the
gap between teeth.
Features
In laryngoscopy, damage to teeth or gums is caused by using the teeth as
the fulcrum point for the laryngoscope while elevating the epiglottis.
Placing the tooth protector on the upper teeth will protect the teeth from
damage by contact with flange of the laryngoscope blade and also from
getting caught in the gap between teeth.
15mm x 22mm Double Swivel with port
We are Manufacturers & Exporters of 15mm x
22mm Double Swivel with port , which is useful in laryngoscopy & other
Operations.
The features of the product are given Below.
Features
Polycarbonate
o It rotates through 360 both at patient and distal ends. Has 15mm Male at
the distal end for breathing circuit and the dual 22mm Male / 15mm Female
connection at patient end, suitable for both 15mm E/T straight connectors
and face masks. The third end (port) has a seal around cap which has been
designed for fibre optic bronchoscopy limb maintaining an airtight breathing
system. The rubber cap may be removed for suctioning, if required.
15mm Modified Ayres T
15mm Modified Ayres T is very
useful to administer oxygen and atmostpheric air in addition to its being a
component of the J.R. Paediatric circuit.
Features
15mm Female on one side for 15mm E/T tracheal connectors, 15mm Male on
other end for breathing circuit or keep open for atmostpheric air and in the
middle a nipple for gas flow. It is very useful to administer oxygen and
atmostpheric air in addition to its being a component of the J.R. Paediatric
circuit.
E/T Tube Holding Band
E/T Tube Holding Band is Specially useful for
patients with beard or patients with burn or other injuries on the face.
Features
Designed to avoid using adhesive tape for tracheal tube fixation. It is
wrapped around the patients head under slight pulling and is fixed
with buttons at the fixation strip. Specially useful for patients with beard
or patients with burn or other injuries on the face.